Server packaging options: Towers, racks and blades


René J Chevance and Pete Wilson, Contributors
10.09.2006
Rating: --- (out of 5)


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


The following tip is excerpted from the chapter on choosing your server from our e-book, "Windows Servers and Storage." In this tip, the authors analyze the various physical forms of server packaging such as towers, racks and blades, and explain where to use them.

Server Packaging
Servers come in a number of physical form factors or packaging, including:

  • Tower: The simplest servers, such as high-end PCs, are provided in tower cases and share similar restrictions in their extensibility.

  • Rack-mount: Larger servers often take rack-mount form. This is a standard, 19-inch wide enclosure that is some multiple of 1.75 inches tall and designed to be mounted into a larger enclosure termed a rack, which allows a site to create an appropriate mix of server configurations. A rack generally integrates some number of services such as power, storage and network connections.

  • Blade: As the technologies used to fabricate components in building server computers has evolved, those components have become more integrated and substantially smaller. This allowed a server to be built on a single board so a rack-mount-sized enclosure could hold many such boards, each with its own processing, memory, network and (minimal) storage. This led to a new form factor for servers: blades. The developing trend is that blades will encroach and take over rack-mount form factors.

Here is a brief summary of these physical form factors and where to use them:

  • The tower form factor is used for low-capacity servers where scalability beyond two towers is not needed.
  • The rack-mount form factor is used to provide servers of substantial capability and multiple nodes, with each node itself being highly capable and configurable.
  • The blade form factor is best suited for servers containing large numbers of nodes of limited capability, each of which typically builds on PC technology with its low cost and small size.

The following table further describes and compares these three packaging options.

TowerRack                                       Blade
What it isA collection of server components (processors, memory, I/O controllers and sometimes some peripherals) integrated within a compact floor-standing unit.A 19"-wide rack into which can be inserted either servers or storage in any mix; the installable units come in heights that are a multiple of 1.75 inches ( "1U"); the maximum height of a rack is 42U.An enclosure equipped to allow a fairly large number of PCI-format cards to be installed within it. Each card is itself a computer system providing processors, memory, network connections and storage connections, a typical configuration being up to four processors, memory, and one or two hard disks for local storage.
What it looks like
Figure 1 - Example of the Tower form factor (Dell PowerEdge 6800)

Figure 2 - Example of the rack mount form factor (HP 9000)

Figure 3 - Example of the blade form factor (IBM BladeCenter)
Where to use itUse a tower system when low cost is a priority, fairly minimal configurations are suitable, scalability is limited and your need for connections to storage or the network is limited.

Physical footprint is small.

Use a rackmount system when each node has to be of fairly large capacity (in terms of number of processors, memory size, storage capacity, etc.), when the overall server configuration should encompass an average to a large number of nodes, and when scalability is important.

Physical footprint is moderate.

Use a blade system when each node has to be of reasonably small capacity (in terms of number of processors, memory size, storage capacity, etc.), when the overall server configuration should encompass an average to a large number of nodes, and when scalability is important.

Physical footprint is fairly small.

Table 1-1: Packaging/Form-factor Comparisons

About the authors:
René J Chevance is an independent consultant. He formerly worked as chief Scientist of Bull, a European-based global IT supplier.

Pete Wilson is Chief Scientist of Kiva Design, a small consultancy and research company specializing in issues surrounding the move to multi-core computing platforms, with special emphasis on the embedded space. Prior to that, he spent seven years at Motorola/Freescale.

More information from SearchWinComputing.com


Rate this Tip
To rate tips, you must be a member of SearchWindowsServer.com.
Register now to start rating these tips. Log in if you are already a member.


Submit a Tip




Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



RELATED CONTENT
Windows Server Monitoring and Management
BitLocker in R2 provides data protection for semi-protected servers
Perfmon made easy with PAL utility
Converting Citrix XenServer source machines to Hyper-V format
Balancing Windows security with reasonable password policies
Windows AppLocker in R2: Turning conventional security wisdom on its head
Top 10 things you don't know about Windows Server 2008 R2
BranchCache makes branch offices feel like home
When to use VM backups versus snapshots in Hyper-V
Installing Server Core for Windows 2008 the easy way
Migrating virtual machines from Microsoft Virtual Server to Hyper-V

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary

DISCLAIMER: Our Tips Exchange is a forum for you to share technical advice and expertise with your peers and to learn from other enterprise IT professionals. TechTarget provides the infrastructure to facilitate this sharing of information. However, we cannot guarantee the accuracy or validity of the material submitted. You agree that your use of the Ask The Expert services and your reliance on any questions, answers, information or other materials received through this Web site is at your own risk.



Server Room Design - Planning, Cooling, Maintenance
HomeTopicsBlogsITKnowledge ExchangeTipsAsk the ExpertsMultimediaWhite PapersIT Downloads
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2004 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts